The following can be read out using the DAS:

^

Whether the lambda performance map has been shifted

^

The direction of the shift (rich or lean)

^

How far the lambda performance map has been shifted

Presentation of self-adjustment value using the DAS

Presentation takes place in the form of a factor and means that the measured air mass value is multiplied by the factor.

Example:

Measured air mass:

150.0 kg/hour

Indicated factor in the DAS:

1.1

To determine the injection duration (fuel injection quantity), the ME-SFI [ME] control unit uses a mathematical air mass value of 165 kg/h (150
kg/hX1.1).

The maximum correction value is -0.68 to +1.32 ms.