Variable Induction Control Valve: Description and Operation

GF07.05-P-6030V Component Description For The Intake Manifold Tumble Flap Switchover Valve

Location

The variable intake manifold switchover valve is mounted at the front of the variable intake manifold.

Task

Pressurize tumble flap switchover aneroid capsule with vacuum or admitting air.

Function

Voltage is supplied from terminal 87. Coil resistance is approx. 30 ohms. The switchover valve is actuated at the ground side by the engine control unit
through its own output stage.

A valve plate actuated by the coil armature switches between the atmospheric memory (ventilation via cap/flap??) and the vacuum memory.