Purpose/Design

Fiber optic conductor interface 

Purpose

The D2B cellular telephone interface (A59/1) is required when a cellular telephone is connected to the digital data bus (D2B) (with code 317, code
318 or code 494a))

Design

-

D2B interface

-

Input for D2B wake-up signal

-

Integrated charger for cellular telephone battery

Function

The D2B interface for portable mobile telephone (A59/1) is switched on and off via a discrete "wake-up" line. It reacts to the descending edge (in the off
state the level is at "high") and the duration of the "wake-up" signal.

NOTE:  Generally the D2B interface for portable mobile telephone (A59/1) remains active for 10 seconds after switching off the D2B interface when
the portable mobile telephone in the holder is switched on.

Control data received from the D2B bus is relayed to the portable mobile telephone via the D2B interface for portable mobile telephone (A59/1) with the
aid discrete data buses; D2B interface for portable mobile telephone (A59/1) switches the portable mobile telephone on or off on request by the 
COMAND operating, display and control module (A40/3) and transfers the functions to be performed (e.g. dialing number).

In the other direction the data from the portable mobile telephone (caller's voice, control data, telephone numbers) are transferred from the D2B interface
for portable mobile telephone (A59/1) in a corresponding D2B format and relayed on to the COMAND operating, display and control module (A40/3)

Vehicles With Code (352A) Comand System|Page 12871 > < Vehicles With Code (352A) Comand System|Page 12869