CL 500 (215.375) V8-5.0L (113.960) (2000)
Blower Motor: Service and Repair
AR83.25-P-1200M Remove/Install Blower Motor
1
Remove cover below instrument panel on right See: Body and Frame/Interior Moulding / Trim/Dashboard / Instrument Panel/Service and Repair
2
Disconnect blower connector
3
Unscrew screws (1)
4
Remove cover (2)
5
Disconnect connector from blower regulator (3)
6
Unscrew screws (4)
7
Remove blower regulator (A32n1)
8
Unscrew screws (5)
9
Remove blower motor (A32m1)
CAUTION: Do not lay blower motor (A32m1) down on impeller.
10
Install in opposite order.