Ignition Coil: Description and Operation
Ignition Coils, Function

Ignition Coils, Function

Each spark plug is actuated separately via its own ignition coil by the ME control unit. Both ignition coils of a cylinder are combined to form a dual
ignition coil. 

The ME control unit actuates the primary wirings (L1) of the double ignition coils at circuits 1a or 1b with ground. 

The primary current flow is interrupted at the moment of ignition timing point. As a result of the sudden collapse of the magnetic field the ignition
voltage is generated in the secondary windings (L2). The ignition voltage flows through the high voltage connection (4a and 4b) and through the spark
plug connector to the respective spark plug (R4). 

The voltage supply of the double ignition coils is protected at circuit 15 (a). 

Diodes are built-in to suppress additional ignition sparks when the primary current is switched on. 

Note: Because of the diodes, it is not possible to measure the resistance in the secondary windings.