mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Electrical - Voltage Drop Testing at The Fuses|Page 8270 > < Electronic Noise Suppressor|Service and Repair
Page 1
background image

Fuse: All Technical Service Bulletins
Electrical - Voltage Drop Testing at The Fuses

Date: April 12, 2006

Order No.: S-B-54.10/162

Supersedes:

Group: 54

SUBJECT: 
Model 164, 171, 199, 203, 208, 209, 210, 211, 215, 219, 220, 221, 230, 251 - 

Quiescent Current Test Via Voltage Drop at the Fuses

This bulletin is for rapidly pinpointing closed-circuit systems responsible for voltage drop. It involves disconnecting fuses or CAN-distributors and
measuring the voltage drop directly at the fuse.

Measuring Voltage Drop:

1.

Testing must be done on the installed fuse of the circuit 30 system (control module) using a suitable multimeter (e.g. Fluke 189) in the microvolt
range.

2.

For an accurate measurement, use appropriately sized pointed probes (Figure 1) to ensure sufficient contact with the opening in the fuse's plastic
housing.

NOTE:

Use probes from the electrical connection set (part no. W 220 589 00 99 00).

The quiescent current can be computed via Ohm's law from the measured voltage value and the internal resistance of the fuse measured.

Electrical - Voltage Drop Testing at The Fuses|Page 8270 > < Electronic Noise Suppressor|Service and Repair