CL 600 (140.076) V12-6.0L (120.982) (1998)
Differential Case: Mechanical Specifications
Axial Play
AXIAL PLAY SPECIFICATIONS
Connecting Flange End Play .................................................................................................................................................................. 0.03-0.30 mm
Tightening
TIGHTENING SPECIFICATIONS
Breather ............................................................................................................................................................................................................. 30 Nm
End Cover Collared Bolt ................................................................................................................................................................................... 50 Nm
END PLAY SPECIFICATIONS
Connecting Flange Axial Play ............................................................................................................................................................ 0.03 to 0.30 mm