CL 600 (215.378) V12-5.8L (137.970) (2002)
1
Remove cover below instrument panel on left
2
Disconnect actuator motor connector (3)
NOTE: Connection and disconnection aid.
3
Unscrew screws (2)
4
Pull off actuator for left center vent diverter flap actuator motor (M16/17)
5
Install in opposite order.
6
Perform synchronization of actuator motors.
AR83.30-P-2080M Remove/Install Actuator For Right Center Diverter Flap
AR83.30-P-2080M Remove/Install Actuator For Right Center Diverter Flap
Revisions
14.10.98 Synchronization of actuator motors Step 11, newly included
1
Remove A/C housing