CL 600 (215.378) V12-5.8L (137.970) (2002)
2
Unscrew screws (3)
3
Disconnect actuator motor connectors (7), unclip wiring harness
NOTE: Connection and disconnection aid.
4
Unclip clips (4)
5
Pull off 2 clips (5)
6
Separate air distribution housing (1) from blower housing (2)
7
Disconnect actuator motor connector (8)
NOTE: Connection and disconnection aid.
8
Unscrew screws (6)
9
Pull off right center vent diverter flap actuator motor (M16/18)
10
Install in opposite order.
11
Perform synchronization of actuator motors.
AR83.30-P-2090M Remove/Install Actuator For Activated Charcoal Filter Flap
AR83.30-P-2090M Remove/Install Actuator For Activated Charcoal Filter Flap
1.1 Remove glove compartment
NOTE: Only model 220
1.2 Remove instrument panel upper section
NOTE: Only model 215
2
Remove passenger airbag
NOTE: Only model 215
3
Unscrew screw (2)
4
Remove lever (3)
5
Unscrew screws (4)
6
Remove cover (5)
7
Disconnect actuator motor connector (6)
NOTE: Connection and disconnection aid
8
Remove actuator motor for activated charcoal filter flap (A32m2)