mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

AR83.30-P-2010M Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 7160 > < AR83.30-P-2010M Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 7158
Page 6
background image

2

Unscrew screws (3)

3

Disconnect actuator motor connectors (7), unclip wiring harness

NOTE:  Connection and disconnection aid.

4

Unclip clips (4)

5

Pull off 2 clips (5)

6

Separate air distribution housing (1) from blower housing (2)

7

Disconnect actuator motor connector (8)

NOTE:  Connection and disconnection aid.

8

Unscrew screws (6)

9

Pull off right center vent diverter flap actuator motor (M16/18)

10

Install in opposite order.

11

Perform synchronization of actuator motors.

AR83.30-P-2090M Remove/Install Actuator For Activated Charcoal Filter Flap

AR83.30-P-2090M Remove/Install Actuator For Activated Charcoal Filter Flap

1.1 Remove glove compartment

NOTE:  Only model 220

1.2 Remove instrument panel upper section

NOTE:  Only model 215

2

Remove passenger airbag

NOTE:  Only model 215

3

Unscrew screw (2)

4

Remove lever (3)

5

Unscrew screws (4)

6

Remove cover (5)

7

Disconnect actuator motor connector (6)

NOTE:  Connection and disconnection aid

8

Remove actuator motor for activated charcoal filter flap (A32m2)

AR83.30-P-2010M Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 7160 > < AR83.30-P-2010M Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 7158