mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF83.70-P-0006-01SX Stationary Heater (STH), Location of Components|Page 10617 > < GF83.70-P-0006-01SX Stationary Heater (STH), Location of Components|Page 10615
Page 15
background image

Heating mode

Heater operation is controlled automatically and is dependent on the coolant temperature. Possible statuses:

^

Full load operation

^

Partial load operation

^

Control interval

Flame formation is monitored during heater operation by the glow pin unit flame monitor. If there is a flame-out, a non-recurring second start is
initialized.

If there is still no flame formation, the fuel supply is terminated by switching off the fuel metering pump and a fault shutoff is performed with
combustion air blower run-on.
The STH switchover valve (Y16) is closed at coolant temperatures less than 60 °C (small coolant circuit). As of 60 °C it is actuated by pulses and the
large coolant circuit is also heated.

Overheating protection

The internal temperature sensing of the STH control unit detects overheating and actuates the heater interrupt run-on with subsequent fault interlock for
approx. 120 s.

Terminate heater operation

The combustion is ended by switching the fuel metering pump off. The combustion air blower run-on time starts.
The run-on time and speed of the combustion air blower is dependent on the operating condition in which the heater unit was switched off.

GF83.70-P-4203SX STH Fuel Metering Pump Component Description

GF83.70-P-4203SX STH Fuel Metering Pump Component Description

- with CODE (228) Stationary heater

Component Identification

Location

The fuel metering pump is installed at the right rear in the vicinity of the fuel tank on the vehicle floor.

Task

The fuel metering pump is a combined supply, metering and shutoff system.

It supplies the fuel required for combustion from the vehicle's fuel tank to the STH or HB heater unit (A6) on model 221 or to the STH heater unit (A6)
on model 216 and shuts off the feed line when the heater unit is deactivated.
Actuation on model 221 is conducted by the STH or HB control unit (A6n1) or on model 216 by the STH control unit (A6n1).

GF83.70-P-4204SXA STH Radio Remote Control Transmitter Component Description

GF83.70-P-4204SXA STH Radio Remote Control Transmitter Component Description

- with CODE (228) Stationary heater [models 216.3, 221.0/1 as of 1.6.06]

'

GF83.70-P-0006-01SX Stationary Heater (STH), Location of Components|Page 10617 > < GF83.70-P-0006-01SX Stationary Heater (STH), Location of Components|Page 10615