Blower Motor: All Technical Service Bulletins
A/C - Delayed Blower Operation On Start Up

Date: January 9, 2008

Order No.: P-B-83.25/107a

Supersedes: P-B-83.25/107 dated October 5, 2007

Group: 83

Revision History

Revision

Date

Purpose

a

1/9/08

Applicable Models and Warranty Information Updated (216 Added)

-

10/5/07

Initial issue

SUBJECT: 
Model 216.371/376/377 
Model 221.171/176/177/179/186

HVAC Blower Delayed Operation on Start-up

If you receive customer reports in the above model vehicles of the HVAC blower not operating on start-up, the blower motor could be the cause. The
blower may start running after driving on a rough road surface. Please diagnose and repair as described below.

1.

Using Star Diagnosis read out fault memory in the climate system control module.

2.

If DTC 9516 is present, follow diagnostic information in Star Diagnosis. If measured values are within specification, do not replace the blower
regulator.

3.

Remove cover below instrument panel on the passenger side. Refer to WIS document AR68.10-P-1520SX.

4.

Turn the blower on. Using your hand, hit the bottom of the blower housing (Figure 1, circle) to try to start the blower. If hitting the housing causes
the blower to start, it confirms the blower is faulty.

5.

If the blower cannot be started by hitting the housing but the results from testing in Step 1 are within specifications, replace the blower motor.
Refer to WIS document AR83.10-P-1100SX.

Note:

Replacing the blower regulator will not correct this symptom.

Parts Information