Function

Vibrations on the crankcase are converted by piezocrystals inside the knock sensors into electrical voltage signals (about 0.13 to 4.7 V). These signals
are transmitted over a 2-pin screened line to the ME control unit (N3/10).

Piezo-electric effect:

An electrical voltage is generated by the mechanical force on a piezo crystal.