CLK 320 (208.365) V6-3.2L (112.940) (1999)
16-pole Data Link Connector (X11/4)
Connect HHT as follows:
Black wire (circuit 31, ground):
socket 1
White wire (circuit 15, voltage):
socket 16
Red wire (circuit 30):
Battery +
or X4/10
Yellow wire to diagnostic output socket of the system being tested.
Connect impulse counter scan tool as follows:
Black wire (circuit 31, ground):
socket 1
Red wire (circuit 15, ignition):
socket 16
Yellow wire to diagnostic output socket of the system being tested.
013
Impulse counter scan tool (alternatively: Hand-Held Tester 087)
087
Hand-Held Tester (HHT) (alternatively: Impulse Counter Scan Tool)
X4/10
Terminal block, circuit 30
X11/4
Data link connector
Adapter cable 965 589 00 50 00 (not shown)
38-pole Data Link Connector (X11/4)
1. Connect HHT with Multiplexer (094) attached to Data link connector X11/4
2. Turn Ignition: ON
3. According to instructions in HHT display:
a) Readout DTC memory/erase
b) Readout Actual values
c) Perform Activations
d) Program control modules
4. Disconnect HHT.
[i]
Observe all system specific instructions listed in the "Preparation for Test' section of each Test Program.