GF83.40-P-2182-01Q Actuator Motor, Automatic Air Conditioning, Task|Page 13205 > < GF83.40-P-2182-01Q Actuator Motor, Automatic Air Conditioning, Task|Page 13203
Page 4
background image

flaps actuator motor (M2/5), the left blending air flap actuator (M2/6), the right blending air flap actuator (M2/7), the left and right footwell flaps
actuator (M2/15), the left and right defroster flaps actuator (M2/16) and the fresh air flaps actuator (M2/21) can be switched on and off.
After being switched on, the actual position of the particular flap stored before being switched off is signaled to the fresh air/ recirculated air flaps
actuator motor (M2/5), the left blending air flap actuator (M2/6), the right blending air flap actuator (M2/7), the left and right footwell flaps actuator
(M2/15), the left and right defroster flaps actuator (M2/16) and the fresh air flaps actuator (M2/21).

During the regulation, the AAC [KLA] control and operating module (N22) cyclically transmits a specified value to the fresh air/ recirculated air flaps
actuator motor (M2/5), the left blending air flap actuator (M2/6), the right blending air flap actuator (M2/7), the left and right footwell flaps actuator
(M2/15), the left and right defroster flaps actuator (M2/16) and the fresh air flaps actuator (M2/21) via a dedicated address. This then decides
accordingly on the direction of rotation and moves automatically to the desired position. The AAC control and operating module (N22) signals its
instantaneous position in response to every cyclic request for the specified value. The AAC control and operating module (N22) compares the received
actual values with the specified values and recognizes whether an actuator motor is located at its specified position or is still running (relevant when
switching off the ignition for saving the actual position).

To protect the fresh air/recirculated air flaps actuator motor (M2/5), the left blending air flap actuator (M2/6), the right blending air flap actuator (M2/7),
the left and right footwell flaps actuator (M2/15), the left and right defroster flaps actuator (M2/16) and the fresh air flaps actuator (M2/21) and to
prevent step losses, these remain stationary if an undervoltage or overvoltage is detected. If the voltage has normalized again, the requested specified
position is approached again automatically.

GF83.40-P-2182Q Actuator Motors For Automatic Air Conditioning, Location/Task/Function

GF83.40-P-2182Q Actuator Motors For Automatic Air Conditioning, Location/task/function

- with CODE (581a) Air conditioning (Automatic)

Component Identification

GF83.40-P-2183-01Q Comfort Automatic Air Conditioning Actuator Motors, Task

GF83.40-P-2183-01Q Comfort Automatic Air Conditioning Actuator Motors, Task

- with CODE (581b) Convenience automatic air conditioning

GF83.40-P-2182-01Q Actuator Motor, Automatic Air Conditioning, Task|Page 13205 > < GF83.40-P-2182-01Q Actuator Motor, Automatic Air Conditioning, Task|Page 13203