Moreover, the COMAND operating, display and control module (A40/3) is always in "stand-by operation" when the CAN passenger compartment bus is
active.

NOTE:  Pressing the "Monitor" button, only changes over between day, night and off mode for the monitor.

Switch-off characteristics when voltage is too low

The COMAND central processor continuously monitors the battery voltage. The system behaves as follows depending on the voltage value:

-

Battery voltage 11.5 to 9.5 V (battery warning range)
If the battery voltage drops to below 11.5 V, a message appears on the display requesting the driver to start the engine.

If the engine is not started, another warning is given after 3 minutes indicating that 10 s still remain to start the engine before the system switches
off. In this case, starting the engine prevents the system from switching off automatically. If the system has switched off and the voltage again
increases to above 11.5 V, the COMAND system does not switch back on automatically.

After switching off, the system can still be switched on manually. The warning procedure is then started again each time for as long as the problem
is not eliminated.

-

Battery voltage less than 9.5 V (voltage too low) 
The COMAND system is automatically switched to a defined stand-by status in which it only continues to monitor the battery voltage. In addition,
the current operating state is stored. In this state, the COMAND system cannot be operated or actuated via Star Diagnosis. Communication with
external components is no longer accomplished.

Cassette Mode, Function

Block diagram of COMAND cassette mode, illustrated with the following equipment:

-

Sound system (code 810)

The marked elements are the components which are essentially used for cassette mode.

3.5 mm standard jack is installed in the glove compartment with which a standard walkman or discman can be connected. The audio signals are
preamplified by the COMAND operating, display and control module (A40/3) and the desired tone settings made (volume, bass, trebble and fader). The