mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Trunk / Liftgate Switch > < Emergency Trunk Release - Retrofit|Page 11034
Page 1
background image

Trunk / Liftgate Shock / Support: Service and Repair

1

Clamp gas-operated strut in vice on drill press.

NOTE:  Ensure that piston rod points away from body and no other persons are in the area of the extended piston rod axis.

2

Drill hole with 3 mm dia. bit in gas-operated strut according to dimension a, approx. 20 mm from bottom of  strut gas-operated (arrow). Drill with
the least possible pressure.

3

Unclamp gas-operated strut and pump gas-operated strut empty by pressing in piston rod a number of times. Dispose of used oil according to
waste disposal laws.

4

Dispose of gas-operated strut (old part).

Trunk / Liftgate Switch > < Emergency Trunk Release - Retrofit|Page 11034