Control Module HVAC: Description and Operation
Electric Suction-Type Fan Control Module (Engine/A/C)

The electric suction-type fan control module (engine/A/C) (N76) switches the engine/A/C electric fan (M4/3) on.

The control module for the electric suction-type fan (engine/A/C) (N76) receives input information on the coolant temperature and refrigerant pressure.

The control module for the electric suction-type fan (engine/A/C) (N76) compares these values with stored values and increases the speed of the electric
suction-type fan (engine/A/C) (M4/3) from 20 % for basic ventilation (with A/C compressor ON) up to 100 % under the following conditions:

-

Refrigerant pressure > 13 bar

-

Coolant temperature > 103 °C

The speed is set back to 20 % basic ventilation under the following conditions:

-

Refrigerant pressure < 12 bar

-

Coolant temperature < 100 °C