mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function|Page 14199 > < GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function
Page 2
background image

Component Identification

Automatic air conditioning (AAC) cooling mode Function

In cooling mode fresh air (A) is drawn in by the blower motor (A32m1) as a result of the position of the fresh air flap and recirculated air flap actuator
motor (M2/5). The air cleaned by the combination filter (1) is led through the cooled evaporator (3), where it is dried and cooled. Then the dried and
cooled air (B) i led past the heated heater heat exchanger (4) due to the position of the left blending air flap actuator motor (M2/6) and right blending air
flap actuator motor (M2/7) and led directly to the air outlets due to the position of the left and right footwell flap actuator motor (M2/15), the left and
right defroster vent flap actuator motor (M2/16) and vent flaps actuator motor (M2/21).

Cooled air (B) is also diverted immediately downstream of the evaporator (3) for indirect ventilation, which is controlled by the cold air addition wheel
at the center vent.
In cooling mode the footwell flaps are closed by the left and right footwell fresh air actuators (M2/15).
The defroster flaps can also be opened when the outside air is dry due to the left and right defroster vent flap actuator motor (M2/16). The other flaps can
be operated manually.
When going from cooling mode to heating mode (mode change) the left and right footwell fresh air actuators (M2/15) start to open. The condensation
water is led to the outside condensation water drain.

Normal mode