Component Identification

Automatic air conditioning (AAC) normal operation Function

In normal mode (AC OFF lights up) fresh air (A) is drawn in by the blower motor (A32m1) due to the position of the fresh air flap and recirculated air
flap actuator (M2/5). The air cleaned by the combination filter (1) is led through the cooled evaporator (3), where it is dried and cooled. Then part of the
dried and cooled a (B) is heated up again in the heated heater heat exchanger (4) due to the position of the left blending air flap actuator motor (M2/6)
and right blending air flap actuator motor (M2/7)t. The remainder of the dried and cooled air is diverted past the heating system heat exchanger (4) and is
blended with the heated air (C) to form blended air (D) downstream of the heating system heat exchanger (4).

Blend air (D) is led to the air outlets due to the position of the left and right footwell flap actuator motor (M2/15), of the left and right defroster vent flap
actuator motor (M2/16) and vent flaps actuator motor (M2/21).
In addition the air (B) cooled directly downstream of the evaporator (3) is diverted for indirect ventilation which is controlled at the center nozzle via the
cold air mixing thumb wheel.
The defroster flaps can be opened when the outside air is dry due to the left and right defroster vent flap actuator motor (M2/16). The other flaps can be
operated manually.
The condensation water is led to the outside condensation water drain.