13

Unscrew nut (1)
-

Nut to expansion valve:  8 N.m

14

Detach pressure lines with retaining plate (2

CAUTION:  Plug openings.

See "Special Tools" below.

CAUTION:  Installation:  replace O-rings (wet with compressor oil).

15

Detach hose clamps (3) from filler neck

CAUTION:  Installation:  mount hose clamp (3) using hose damp pliers at an angle of 45 degrees (Fig. A).

-

Hose clamp pliers (length 210 mm; tensioning range 80 mm)
See "Commercially Available Tools" below.

16

Detach hot-water supply hose (4)

CAUTION:  Seal opening.

See "Special Tools" below.

17

Detach hose clamp (5) from filler neck

CAUTION:  Installation:  mount hose clamp (5) using hose clamp pliers at an angle of 45 degrees (Fig. B).

-

Hose clamp pliers (length 210 mm; tensioning range 80 mm)
See "Commercially Available Tools" below.

18

Detach hot-water return flow hose (6)

CAUTION:  Seal opening.

See "Special Tools" below.

19

Remove condensed water drainage hose (7)

20

Detach coupling (8) from evaporator temperature sensor (B10/6)

21

Remove evaporator housing slightly from firewall

22

Remove cockpit wiring harness (9) from evaporator housing

23

Remove evaporator housing
-

MB long-term grease

24

Install in the reverse order

25

Read diagnostic trouble code memory and erase

26

Normalize actuator motors

27

Perform basic programming.

Special Tools

Set of Plugs, P/N# 129 589 00 91 00

Commercially Available Tools

AR83.30-P-5200Q Remove/Install AC Housing|Page 14221 > < AR83.30-P-5200Q Remove/Install AC Housing|Page 14219