Air Door Actuator / Motor: Description and Operation
GF83.40-P-2182-02Q Automatic Air Conditioning Actuator Motors, Function

GF83.40-P-2182-02Q Automatic Air Conditioning Actuator Motors, Function

- with CODE (581a) Air conditioning (Automatic)

Function

The actuator motors

-

Fresh air flap and recirculated air flap actuator motor (M2/5),

-

Left blend air door actuator motor (M2/6),

-

Right blend air door actuator motor (M2/7),

-

Left and right footwell flap actuator motors (M2/15)

-

Left and right defroster vent flap actuator motor (M2/16),

-

Fresh air flaps actuator (M2/21)

of the AAC housing are actuated directly by the AAC [KLA] control and operating module (N22) via the AC bus.

Integrated into the AAC [KLA] control and operating module (N22) is an output stage, with which the battery voltage for the fresh air/ recirculated air
flaps actuator motor (M2/5), the left blending air flap actuator (M2/6), the right blending air flap actuator (M2/7), the left and right footwell flaps
actuator (M2/15), the left and right defroster flaps actuator (M2/16) and the fresh air flaps actuator (M2/21) can be switched on and off.
After being switched on, the actual position of the particular flap stored before being switched off is signaled to the fresh air/ recirculated air flaps
actuator motor (M2/5), the left blending air flap actuator (M2/6), the right blending air flap actuator (M2/7), the left and right footwell flaps actuator
(M2/15), the left and right defroster flaps actuator (M2/16) and the fresh air flaps actuator (M2/21).

During the regulation, the AAC [KLA] control and operating module (N22) cyclically transmits a specified value to the fresh air/ recirculated air flaps
actuator motor (M2/5), the left blending air flap actuator (M2/6), the right blending air flap actuator (M2/7), the left and right footwell flaps actuator
(M2/15), the left and right defroster flaps actuator (M2/16) and the fresh air flaps actuator (M2/21) via a dedicated address. This then decides
accordingly on the direction of rotation and moves automatically to the desired position. The AAC control and operating module (N22) signals its
instantaneous position in response to every cyclic request for the specified value. The AAC control and operating module (N22) compares the received
actual values with the specified values and recognizes whether an actuator motor is located at its specified position or is still running (relevant when
switching off the ignition for saving the actual position).

To protect the fresh air/recirculated air flaps actuator motor (M2/5), the left blending air flap actuator (M2/6), the right blending air flap actuator (M2/7),
the left and right footwell flaps actuator (M2/15), the left and right defroster flaps actuator (M2/16) and the fresh air flaps actuator (M2/21) and to
prevent step losses, these remain stationary if an undervoltage or overvoltage is detected. If the voltage has normalized again, the requested specified
position is approached again automatically.