Page 5
background image

11

Perform basic programming.

AR83.10-P-2003Q Remove/Install Actuator For Right Blend Air Flap

AR83.10-P-2003Q Remove/Install Actuator For Right Blend Air Flap

- without CODE (581b) Convenience automatic air conditioning

DANGER:

-

Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury with caustic
burns to eyes and skin from battery electrolyte or from handling damaged lead-acid batteries

-

No fire, sparks, naked flames or smoking.

-

Wear acid-resistant gloves, clothing and eye protection. Pour battery electrolyte only into suitable and appropriately marked containers.

1

Disconnect ground cable of battery

2

Remove glove compartment

3

Remove cover below instrument panel

NOTE:  Passenger side.

4

Unscrew bolts (1)

NOTE:  Three bolts.

5

Remove right blending air flap actuator motor (M2/7)

6

Detach coupling (3)

7

Install in the reverse order

8

Normalize right blending air flap actuator motor (M2/7)

9

Read diagnostic trouble code memory and erase

10

Perform basic programming.

AR83.10-P-2004Q Remove/Install Actuator For Left Defroster Vent Flap

AR83.10-P-2004Q Remove/Install Actuator For Left Defroster Vent Flap

- with CODE (581b) Convenience automatic air conditioning

AR83.10-P-2001Q Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 11758 > < AR83.10-P-2001Q Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 11756