mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function|Page 12210 > < GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function|Page 12208
Page 8
background image

The air ducting depends on various operating conditions such as:

^

Heating mode

^

Cooling mode

^

Normal mode

^

Blended air mode

GF83.40-P-2170-03Q Convenience Automatic Air Conditioning Box Function

GF83.40-P-2170-03Q Convenience Automatic Air Conditioning Box Function

- with CODE (581b) Convenience automatic air conditioning

Heating mode

Component Identification

Heating mode with activated charcoal filter convenience automatic air conditioning (C-AAC)

Settings:

-

AC OFF Off

-

Both AUTO buttons pressed

-

Activated charcoal filter mode ON

-

Recirculated air mode OFF

Function

In the heating mode, fresh air (A) is drawn in by the blower motor (A32m1) as a result of the position of the fresh air/recirculated air flaps actuator motor
(M2/5). The air, which is purified by the dust filter (1), is conducted as a result of the position of the activated charcoal filter flap adjustment motor
(A32m2) through the two activated charcoal filters (2) and passes through the cooled evaporator (3), is dried there and cooled. Then the dried and cooled
air (B) is heated up again due to the position of the left blending air flap actuator motor (M2/6) and the right blending air flap actuator motor (M2/7) in
the heater heat exchanger (4).

The heated air (C) is conducted to the air outlets, due to the position of the left defroster vent flap actuator motor (M2/8) and the right defroster vent flap
actuator motor (M2/9), the left footwell flap actuator motor (M2/10), the right footwell flap actuator motor (M2/11), the left fresh air flap actuator
(M2/19) and the right fresh air flap actuator (M2/20):

^

Footwell Open

^

Vent nozzles Open

^

Defroster nozzles restricted

GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function|Page 12210 > < GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function|Page 12208