mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function|Page 12211 > < GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function|Page 12209
Page 9
background image

^

Other flaps can be operated manually

The cooled air (B) is also diverted immediately downstream of the evaporator (3) for indirect ventilation, which is controlled by the cold air addition
wheel at the center vent.
In this function, the defroster flaps of the left defroster vent flap actuator motor (M2/8) and the right defroster vent flap actuator motor (M2/9) are
slightly open.
During the transition from heating mode to cooling mode (mode change), the footwell flaps of the left footwell flap actuator motor (M2/10) and the right
footwell flap actuator motor (M2/11) begin to close.
The condensation water is led to the outside condensation water drain.

Cooling mode

Component Identification

Cooling mode with activated charcoal filter convenience automatic air conditioning (C-AAC)

Settings:

-

AC OFF Off

-

Both AUTO buttons pressed

-

Activated charcoal filter mode ON

-

Recirculated air mode OFF

Function

In the cooling mode, fresh air (A) is drawn in by the blower motor (A32m1) as a result of the position of the fresh air/recirculated air flaps actuator
motor (M2/5). The air, which is purified by the dust filter (1), is conducted as a result of the position of the activated charcoal filter flap adjustment
motor (A32m2) through the two activated charcoal filters (2) and passes through the cooled evaporator (3), is dried there and cooled. Then the dried and
cooled air (B), due to the position of the left blending air flap actuator motor (M2/6) and the right blending air flap actuator motor (M2/7), is conducted
past the heater heat exchanger (4).

The dried and cooled air (B) is then conducted directly to the air outlets, due to the position of the left defroster vent flap actuator motor (M2/8) and the
right defroster vent flap actuator motor (M2/9), the left footwell flap actuator motor (M2/10), the right footwell flap actuator motor (M2/11), the left
fresh air flap actuator (M2/19) and the right fresh air flap actuator (M2/20).

The cooled air (B) is also diverted immediately downstream of the evaporator (3) for indirect ventilation, which is controlled by the cold air addition
wheel at the center vent.
In cooling mode, the footwell flaps are closed via the left footwell flap actuator motor (M2/10) and the right footwell flap actuator motor (M2/11).
Using the left defroster vent flap actuator motor (M2/19) and the right defroster vent flap actuator motor (M2/20), the defroster vent flaps can be opened

GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function|Page 12211 > < GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function|Page 12209