mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function|Page 12213 > < GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function|Page 12211
Page 11
background image

As the result of the position of the left defroster vent flap actuator motor (M2/8) and the right defroster vent flap actuator motor (M2/9), the defroster
vent flaps can be opened if the outside air is dry.

Blended air mode with recirculated air

Component Identification

Blended air mode with recirculated air and activated charcoal filter convenience automatic air conditioning (C-AAC)

Settings:

-

AC OFF On

-

Both AUTO buttons pressed

-

Activated charcoal filter mode ON

-

Recirculated air mode On

Function

In the mixed air mode with recirculated air (AC OFF lit up), recirculated air is drawn in by the blower motor (A32m1) as a result of the position of the
fresh air/recirculated air flaps actuator motor (M2/5). This is conducted as a result of the position of the activated charcoal filter flap adjustment motor
(A32m2) through the two activated charcoal filters (2) and passes through the cooled evaporator (3), where it is dried and cooled. Then some of the dried
and cooled air (B) is heated up again due to the position of the left blending air flap actuator motor (M2/6) and the right blending air flap actuator motor
(M2/7) in the heated heat exchanger (4).

The remainder of the dried and cooled air is diverted past the heating system heat exchanger (4) and is blended with the heated air (C) to form blended
air (D) downstream of the heating system heat exchanger (4).

The mixed air (D), via the position of the left defroster vent flap actuator motor (M2/8) and the right defroster vent flap actuator motor (M2/9), the left
footwell flap actuator motor (M2/10), the right footwell flap actuator motor (M2/11), the left fresh air flap actuator (M2/19) and the right fresh air flap
actuator (M2/20), is conducted to the air outlets:

-

Footwell Open

-

Vent nozzles Open

-

Defroster nozzles restricted

-

Other flaps can be operated manually

Cooled air (B) is also diverted immediately downstream of the evaporator (3) for indirect ventilation, which is controlled by the cold air addition wheel
at the center vent.
Using the left defroster vent flap actuator motor (M2/8) and the right defroster vent flap actuator motor (M2/9), the defroster vent flaps can be opened if
the outside air is dry.

GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function|Page 12213 > < GF83.40-P-2105-02Q Automatic Air Conditioning Box, Function|Page 12211