mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

AH00.19-P-1000-02A Notes on Replacing Safety-Relevant Components|Page 7758 > < AH00.19-P-1000-02A Notes on Replacing Safety-Relevant Components|Page 7756
Page 8
background image

Overview (Lines/Contacts)

Overview (lines/Contatcts To Components)

AH00.19-P-1000-09A Notes on Crimping

AH00.19-P-1000-09A Notes On Crimping

1

Check crimped connections for correct forming and filling (cross-section, ensure that leads are enclosed correctly).

Correct crimped connection (A):
The strands of the cable are evenly enclosed.
The crimp tab is evenly shaped.

Incorrect crimped connection (B):
The crimp tab has an incorrect cross-section and is not full enough.

Incorrect crimped connection (C):
Individual wire strands are outside the crimp shackle.
The crimp tab is too full.

Incorrect crimped connection (D):
The crimp claws touch the bottom of the crimped fitting.
The crimp tab is too full.
The crimp tab is deformed and therefore damaged.

Shown with circular conductor