mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

AR83.10-P-2001Q Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 10062 > < AR83.10-P-2001Q Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 10060
Page 11
background image

DANGER:

-

Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of injury with caustic
burns to eyes and skin from battery electrolyte or from handling damaged lead-acid batteries

-

No fire, sparks, naked flames or smoking.

-

Wear acid-resistant gloves, clothing and eye protection. Pour battery electrolyte only into suitable and appropriately marked containers.

1

Disconnect ground cable of battery

2

Remove instrument panel

3

Unscrew bolts (1)

NOTE:  Three bolts.

4

Remove left and right defroster vent flap actuator motors (M2/8)

5

Detach coupling (3)

6

Install in the reverse order.

7

Normalize left and right defroster vent flap actuator motors (M2/8).

8

Read diagnostic trouble code memory and erase.

9

Perform basic programming.

AR83.10-P-2010Q Remove/Install Actuator For Left Vent Flap

AR83.10-P-2010Q Remove/Install Actuator For Left Vent Flap

- with CODE (581) Convenience automatic air conditioning

AR83.10-P-2001Q Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 10062 > < AR83.10-P-2001Q Remove/Install Actuator For Fresh and Recirculated Air Flaps|Page 10060