2

Remove evaporator housing

3

Unscrew bolts (1)

NOTE:  Two bolts.

4

Remove activated charcoal filter flap adjustment motor (A32m2)

5

Detach coupling (3)

6

Install in the reverse order

7

Normalize activated charcoal filter flap adjustment motor (A32m2).

8

Read diagnostic trouble code memory and erase

9

Perform basic programming.