mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF82.85-P-0003-06TXA Cockpit Management and Data System (COMAND) Volume/Tone Setting|Page 13787 > < GF82.85-P-0003-06TXA Cockpit Management and Data System (COMAND) Volume/Tone Setting|Page 13785
Page 3
background image

off and the voltage rises again above 11.5 V, the COMAND operating, display and controller unit does not switch on again.

^

If a system has been shut down it can still be switched back on again manually. However, the warning procedure recurs each time anew until the
fault has been rectified.

Battery voltage below 9.5 V (undervoltage)

The COMAND operating, display and controller unit is automatically put into a defined standby condition in which only the battery voltage is
monitored. Additionally, the current operating condition is backed up. In this condition the system cannot be operated or made to respond via STAR
DIAGNOSIS. All communication with external components is stopped.

Switch On/Off characteristics with code (889) Keyless Go

If the vehicle is started or stopped by pressing the Keyless Go switch start/stop switch (S2/3), this is identical to the switching on/ off behavior when
starting up again with the transmitter key.

GF82.85-P-0003-07TXJ Cockpit Management and Data System (COMAND), Switch-On/Off
Characteristics

GF82.85-P-0003-07TXJ Cockpit Management And Data System (COMAND), Switch-On/Off Characteristics

- with CODE (498) Japan version

Activation of entire system

In order to ensure a quicker switch-on process, all bus systems are activated by inserting the transmitter key (A8/1) in the EIS [EZS] control unit (N73)
in position 0 (circuit 15C). If the transmitter key (A8/1) is in position 1 (circuit 15R ON), the display of the COMAND operating, display and control
unit (A40/3) is switched on. This works if it was switched on before the transmitter key (A8/1) was last removed.
The system which was active before it was last switched off (e.g. radio) is switched on and the corresponding basic menu is displayed. If the COMAND
operating, display and control unit (A40/3) was switched off for more than 30 minutes, then a message appears with general information about how to
use the system.

Conduct when pushing "ON" button

The COMAND operating, display and control unit (A40/3) can also be switched on when the transmitter key (A8/1) is removed by pressing the "ON"
button. All functions are then available for t = 30 minutes

Activating navigation

The navigation system is activated automatically via the class B (interior) controller area network bus (CAN-B) when the driver door is opened. If the
digital versatile disk (DVD) is inserted, this process may be accompanied by faintly audible noises from the integrated DVD drive. The display of the
COMAND operating, display and control unit (A40/3) remains switched off. If, as a result of this, no status change occurs at the EIS [EZS] control unit
(N73), e.g. "circuit 15C ON" or "circuit 15R ON", the navigation system remains activated for t = 30 minutes. When 30 minutes has elapsed, the
COMAND operating, display and control unit (A40/3) switches itself off automatically. If switching off has occurred after 30 minutes, the system can be
switched on again by pressing the "ON" button, the 30-minute run-on time starts again.

Following the final navigation step (destination reached) the position map is shown again in the display.

Switch off characteristics

The COMAND operating, display and control unit (A40/3) is switched off when the transmitter key (A8/1) is removed "circuit 15C OFF". The 
navigation system run-on time of t = 30 min starts (standby). During the run-on time, all the important locating parameters are stored. The run-on time of
the audio systems can be adjusted and is set in the plant when the COMAND operating, display and control unit (A40/3) is installed. Moreover the
COMAND operating, display and control unit (A40/3) is always in "standby" when CAN-B is active.

Switch off characteristics at undervoltage

The COMAND operating, display and control unit (A40/3) constantly monitors battery voltage. Depending on the voltage value the system will act as
follows:

Battery voltage below 11.5 V and >=9.5 V

If the battery voltage decreases below 11.5 V (battery warning range), a message appears in the display of the COMAND operating, display and control
unit (A40/3), which requests that the engine be started. If the engine is not started, another warning is issued after t = 3 min that there are 10 s left to start
the engine before the system shuts off. In this case switching on the engine prevents the system from being automatically shut down. If the system has
shut off and the on-board power supply increases to more than 11.5 V again, the COMAND operating, display and control unit (A40/3) does not switch
itself on again automatically.

GF82.85-P-0003-06TXA Cockpit Management and Data System (COMAND) Volume/Tone Setting|Page 13787 > < GF82.85-P-0003-06TXA Cockpit Management and Data System (COMAND) Volume/Tone Setting|Page 13785