Blower Motor: Technical Service Bulletins
A/C - Unnecessary Blower Motor Replacement

Date: October 20, 2003

Order No.: P-B-83.40/68

Supersedes:

Group: 83

SUBJECT:
Model 210.025/065/070/074/082/083/265/282 

As of A735001

Unnecessary Replacement of Air Conditioning Blower Motor

If you receive customer reports in the above models regarding poor or no operation of the air conditioning blower motor, trial install just the regulator
before replacing the blower motor. Testing has found that in almost all cases when the blower motor is replaced together with the regulator, the blower
motor is replaced unnecessarily. As of repair date October 27, 2003, all blower motors will be tested and if no fault is found, the blower will be returned
and the claim will be debited.