mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Auxiliary Fan Control Module|Page 9411 > < Auxiliary Fan Control Module New Version|Page 9408
Page 1
background image

Control Module HVAC: Description and Operation
Auxiliary Fan Control Module

Model

210
with ENGINE104 as of September 9, 1996 up to Febuary 28, 1997

602, 604, 605, 606 up to September 1, 1996
112 up to May 31, 1998
113 as of March 1, 1997

with CODE (580) Air Conditioning or Tempmatic A/C for USA
with CODE (581a) Air Conditioning (automatic)

The auxiliary fan control module switches on the auxiliary fan.

The push-button control module controls the AIR control module (N65/1) with a minimum of 3 mA and max. 10 mA.
The AIR control module (N65/1) compares these values with stored values and switches on the auxiliary fan (M4) under the following conditions:

-

Outdoor temperature

=

>5 °C

-

Refrigerant pressure

=

13 bar

-

Coolant temperature

=

103 °C

-

Limp-home mode (e.g. refrigerant pressure 20 bar)

The auxiliary fan (M4) is switched off under the following conditions:

-

Refrigerant pressure

=

12 bar

-

Coolant temperature

=

100 °C

Auxiliary Fan Control Module|Page 9411 > < Auxiliary Fan Control Module New Version|Page 9408