Vent valve function

-

Air release from fuel tank
The vent valve (4) opens at a pressure of 30 - 50 mbar: fuel vapors flow to the activated charcoal canister.

-

Air admission to fuel tank
The air admission valve (6) opens at a vacuum of 1 - 16 mbar in the fuel tank. Air or fuel vapors are drawn in through the activated charcoal
canister. 

-

Refueling
The opening pressure of the vent valve (4) of 30 - 50 mbar is not achieved when the fuel tank filler cap is removed. The vent line to the activated
charcoal canister remains sealed off. The refueling nozzle switches off more rapidly.