mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Without Level Control and Adaptive Damping System (ADS)|Page 8324 > < Without Level Control and Adaptive Damping System (ADS)|Page 8322
Page 4
background image

Figure 2 (Volume Control Valve (t30) Closed

ENGINE ON, STEERING WHEEL TURNED

The pressure behind the volume control valve also increases due to the increasing pressure level behind the restrictor (a). The volume control
valve (30t) closes (Figure 2) and remains in its initial position.

INCREASED ENGINE SPEED 

If the oil quantity increases as engine speed increases, a greater pressure difference occurs again due to the calibrated bore (9a). The volume
control valve (30t) is pressed against the spring (30s) and the excess oil quantity delivered can flow back into the reservoir (Figure 1). 

PRESSURE LIMITATION 

A pressure limiting valve (49d) is installed in the volume control valve (30t) to protect the steering system against overload. It opens between a
pressure of 65 and 125 bar depending on the type of power steering pump.

This occurs at full steer angle for example, which is audible as a shrill whirring whistling sound.

Radial Piston Pump

Radial Piston Pump

Without Level Control and Adaptive Damping System (ADS)|Page 8324 > < Without Level Control and Adaptive Damping System (ADS)|Page 8322