Window Track: Customer Interest
Body - Side Window(s) Open After One-Touch Closing

Date: December 30, 2004

Order No.: P-B-67.30/12

Supersedes:

Group: 67

SUBJECT:
Model 202.022/023/024/028/029/033 

Model 210.020/025/065/070/072/074/082/083/265/282 

Side Window(s) Open After One-Touch Closing

If you receive customer reports in the above model vehicles of the side windows opening slightly after closing with the one-touch feature, check for a
mechanical problem by following the below steps. In most cases, the reason for this is that the window mechanism detects a mechanical resistance and
opens approximately 5 cm as designed. To correct, the source mechanical resistance needs to be removed.

1.

Check window guide - The dimension between the front and rear window guides (window frame) must be identical at the top and bottom and the
door window must have a constant 1 mm of play (clearance) from top to bottom.

2.

Check door window - The door window must move with smoothness from top to bottom. Make sure the door window slots easily and completely
into the upper (horizontal) window guide.

3.

Check window guide - In the upper, front and rear corners, the window guide must be seated correctly at right angles or seated properly in the
corners.

4.

Re-normalize power windows - Hold down power window switch at the first detent for longer than 1 second after the window has closed. It is
possible to de-normalize the power window using the HHT and then re-normalize it as described above.

If none of these measures is successful, the radius of the door window should also be checked.

Note

The following allowable labor operations should be used when submitting a warranty claim for this repair.