Ensure malfunctioning regulator is inspected (refer to step 3 of this section) prior to replacing.

^

Ensure circuit 30 systems are reinitialized and fault codes are erased (refer to steps 8 and 9 of this section).

1.

Remove the two nuts (1, Figure 16) from studs and one Philips head screw (2); remove the plastic cover from the rear of  the alternator.

Note:

Observe which nut is removed from either stud.

2.

Remove three Philips head screws (2, 3, Figure 17); remove voltage regulator (1) from the alternator.

3.

Inspect wear shape (arrow, Figure 18) of carbon brushes: If brushes have worn at an angle (arrow), alternator bearing damage is indicated and the 
alternator must be replaced. If brushes wear is normal, continue with regulator replacement.