mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF07.04-P-6100GZ Component Description For a O2 Sensor|Page 6842 > < GF07.04-P-6100GZ Component Description For a O2 Sensor|Page 6840
Page 1
background image

Oxygen Sensor: Description and Operation
GF07.04-P-6100TU Component Description For A O2 Sensor

GF07.04-P-6100TU Component Description For A O2 Sensor

- with CODE (494) USA version

Component Identification

Location

The O2 sensor upstream of TWC is located at the front in the NOx catalytic converter, behind the turbocharger. The O2 sensor downstream of TWC is
located behind the NOx catalytic converter.

Task of the O2 sensor upstream of TWC

The O2 sensor upstream of TWC detects the residual oxygen content in the exhaust and passes on an appropriate signal to the CDI control unit (N3/9).
Secondary injection amounts for regeneration operation of the NOx catalytic converter is regulated depending on the determined residual oxygen
content.

Task of the O2 sensor downstream of TWC

The O2 sensor upstream of TWC detects the residual oxygen content in the exhaust downstream of the NOx catalytic converter and passes on an
appropriate signal to the CDI control unit. The period of regeneration operation of the NOx catalytic converter is regulated depending on the determined
residual oxygen content.

Design

The O2 sensor used upstream TWC is designed as a wideband oxygen sensor. The wideband oxygen sensor consists of a pump cell, a concentration cell
and a heating element. The heating element maintains the temperature of the ceramic probe body constant at 780 °C. The conductivity of the ceramic
probe body is temperature- dependent.

Function

Via a small gas entry hole in the pump cell, the exhaust gas reaches the measuring chamber of the concentration cell. The oxygen from the exhaust is
pumped into a reference chamber which serves as the oxygen reference. By application of a voltage to the platinum electrodes of the pump call. oxygen
can be pumped into or out of the reference chamber. An evaluation module in the CDI control unit regulates the voltage applied to the pump cell so that
the mixture composition in the measuring chamber is continuously adjusted to the value lambda= 1. In the case of lean exhaust gas the pump cell pumps
oxygen out of the measuring chamber. The pump flow is thus positive.

If, however, the exhaust gas is rich, then oxygen at the platinum electrodes is pumped via the catalytic decomposition of carbon dioxide (CO ) and water

GF07.04-P-6100GZ Component Description For a O2 Sensor|Page 6842 > < GF07.04-P-6100GZ Component Description For a O2 Sensor|Page 6840