mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF82.25-P-0003T Emergency Alarm, Function|Page 18411 > < GF82.25-P-0003T Emergency Alarm, Function|Page 18409
Page 2
background image

Depending on the version code entered in the multifunction control unit for special-purpose vehicles (SVMCU [MSS]) (N26/9) no there may be audible
or visible confirmation signal to verify that the emergency alarm system has been triggered. The silent alarm is not noticeable.

Silent alarm (1st level)

The silent alarm emergency alarm is activated by pressing the system activate button (S62/6) once. The system responds with the following:

^

the roof sign (E14/4) flashes (2.5 Hz)

^

the service radio (A49) is switched to its monitor mode (alarm mode).

^

the left high beam (E1e1) and right high beam (E2e1) flash on and off

The silent alarm is specifically designed to prevent the threatening individual from becoming aware that an alarm has been given.

Cancelation of Silent Alarm (Stage 1)

The alarm is terminated by pressing the emergency alarm system cancel switch (S62/5) one time. This button is located in the vehicle's luggage
compartment.
Following cancelation of the alarm all of the systems that it acts upon will revert to their initial operational status.

Active alarm (2nd level)

The active alarm emergency alarm is activated by pressing the system activate button (S62/6) twice (within 3 seconds) or by pressing twice (within 3
seconds) via the taxi emergency alarm two-way radio remote activation transmitter (A8/4) . The system responds with the following:

^

the roof sign (E14/4) flashes (2.5 Hz)

^

the service radio (A49) is switched to its monitor mode (alarm mode).

^

the horns (H2) assume intermittent operation (1.6 Hz)

^

the left high beam (E1e1) , flash on right high beam (E2e1) and off (0.8 Hz)

^

all turn signals flash (2.5 Hz)

^

the front dome lamp (N70e1) rear courtesy lamp and the (E15/3)remain on until the emergency alarm system cancelation button (S62/5) is
activated.

Cancelation when activating Active Alarm (Stage 2)

The alarm is terminated by pressing the emergency alarm system cancel switch (S62/5) one time. This button is located in the vehicle's luggage
compartment. Following cancelation of the alarm all of the systems that it acts upon will revert to their initial operational status.

Turn signal operation sequence When several systems or devices simultaneously transmit operation requests directed at the turn signals through the
vehicle's on-board CAN the defined response sequence is as follows:
priority 1:

taxi emergency alarm

priority 2:

EDW

priority 3:

turn signal indicator function; hazard flashers; open/close

priority 4:

hazard warning flashers

Variants

Star Diagnosis can be used to activate and deactivate all individual functions to achieve compliance with various national regulations and/or individual
client requests. In addition, the multifunction control unit provides
special-purpose vehicles (SVMCU [MSS]) (N26/9) with the additional option of actuating the LED roof sign lamps. In the event of an alarm's being
actuated, the control unit output pole is constantly incorrectly connected thereby allowing the LED to flash with a frequency of 3.7 Hz.

The Star Diagnosis can also be used to deactivate the Silent Alarm function; then pressing the emergency alarm system activate button (S62/6) Active
Alarm once will initiate the (2nd level).

GF82.25-P-0003T Emergency Alarm, Function|Page 18411 > < GF82.25-P-0003T Emergency Alarm, Function|Page 18409