mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Recall - SBC Wire Harness Modifications|Page 11499 > < Recall - SBC Wire Harness Modifications|Page 11497
Page 30
background image

(B).

Note:

^

Ensure that the SBC wiring harness (A) is properly routed so that it is free of tension in the SBC connector housing.

^

The cable tie "buckle" (D) must be located at the side of the connector cover harness receptacle (arrow) as depicted.

14.

Secure ground wiring harness (C, Figure 13) to the SBC connector housing receptacle (F) using a new cable tie (E).

15.

Attach bracket (A, Figure 16) to the SBC hydraulic unit (B, Figure 16):

Recall - SBC Wire Harness Modifications|Page 11499 > < Recall - SBC Wire Harness Modifications|Page 11497