mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Procedures|Page 12300 > < Outlet Control Valve, Front, Left|Page 12297
Page 1
background image

Hydraulic Control Assembly - Antilock Brakes: Procedures

AR42.46-P-0010R Remove/Install Sensotronic Brake Control (SBC) Hydraulic Unit

Remove/Install Sensotronic Brake Control (SBC) Hydraulic Unit

Shown On Model 230.475

Remove/Install

DANGER:

-

Risk of injury, body parts may become jammed or crushed. Risk of injury, skin and eyes may be injured due to brake fluid spraying out
at high pressure when working on the SBC brake system

-

Deactivate SBC brake system using STAR DIAGNOSIS.

-

Risk of poisoning from swallowing brake fluid. Risk of injury from brake fluid coming into contact with skin and eyes.

-

Pour brake fluid only into suitable and appropriately marked containers. Wear protective clothing and eye protection when handling
brake fluid.

1

Deactivate SBC brake system using STAR DIAGNOSIS.

2

Remove key from ignition lock

NOTE:  Vehicles with Keyless Go code (889): Press start/stop button repeatedly until the ignition is switched off.

3

Unplug electrical connector from SBC control module (A7/3n1)

4

Remove right air intake pipe (1)
-

Model 230.467/475

5

Remove air cleaner housing

6

Mark hydraulic lines

7

Detach hydraulic lines from SBC hydraulic unit (A7/3)

CAUTION:  Before opening the SBC system, thoroughly clean the surrounding area of the separation point. Even the smallest particles
of dirt, introduced into the hydraulic components, can lead to malfunctions and a total failure of the SBC system.

NOTE:
-

Collect any brake fluid which runs out in a fluff-free, absorbent cloth. Seal hydraulic lines and connections on the SBC hydraulic unit (A7/3)
immediately with blind plugs.

-

Installation:  Do not mix up hydraulic lines, observe markings.

CAUTION:  See notes on handling brake fluid

8

Disconnect suction line (2)

CAUTION:  Seal suction line and connection on SBC hydraulic unit (A7/3) immediately with blind plugs in order to avoid damage due to
brake fluid running out.

9

Detach return line from SBC hydraulic unit (A7/3)

CAUTION:  Seal suction line and connection on SBC hydraulic unit (A7/3) immediately with blind plugs in order to avoid damage due to
brake fluid running out.

Procedures|Page 12300 > < Outlet Control Valve, Front, Left|Page 12297