Recall - SBC Wire Harness Modifications|Page 12501 > < Recall - SBC Wire Harness Modifications|Page 12499
Page 34
background image

Note:

^

The ground wire harness (arrow) must be routed under the SBC suction hose (C). The ring connector (A) must be positioned as shown in Figure
20.

^

This ground terminal (B) is to be used only for mounting the SBC ground wire harness (arrow).

20.

Connect SDS and check software release:

Note:

Ensure only the following versions of DAS are used:

^

11/2005 with SBC patch 479 installed on SDS

^

Any DAS version after 11/2005

Navigate through the following menu items in DAS and follow on-screen instructions:

"Control units/Chassis/SBC - Sensotronic Brake Control/Control unit adaptations".

Note:

^

Ensure to follow the on-screen instructions in DAS for connecting programming and terminal inspection tool to the SBC hydraulic unit.

^

In the event of malfunctions during the SBC programming, a message will appear in the DAS display and a troubleshooting guide will be
displayed.

^

In the event DAS indicates that the SBC hydraulic unit requires replacement after inspecting SBC connector terminals, refer to WIS:
AR42.46-P-0010R (for replacement instructions).

^

Note (regarding above WIS instructions):

Disregard WIS notes regarding brake bleeder pressure. The maximum pressure for brake bleeder is 2.5 bar.

21.

Secure SBC wiring harness (A, Figure 21) to SBC hydraulic unit bracket (B) with cable tie (arrow). Tighten cable tie (arrow) using Hellermann
MK9 cable tie pliers (Special Tool W 352 589 02 37 00); use setting 3 on cable tie pliers.

Recall - SBC Wire Harness Modifications|Page 12501 > < Recall - SBC Wire Harness Modifications|Page 12499