mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF83.40-P-2182-01T Actuator Motor, Automatic Air Conditioning, Task|Page 16169 > < GF83.40-P-2182-01T Actuator Motor, Automatic Air Conditioning, Task|Page 16167
Page 3
background image

7 o'clock

8 o'clock

9 o'clock

10 o'clock 11 o'clock 12 o'clock

54%

30%

0%

0%

0%

0%

Automatic footwell flap control

The footwell flaps are opened depending on the following values

^

Blend air flap position

^

Coolant temperature

^

Evaporator temperature

linear up to 100 % open.

Fresh air and recirculated air flap actuator motor (M2/5)

The fresh air flap/recirculated air flap actuator motor (M2/5) is used to close or open the fresh air supply by operating the fresh air flaps and recirculated
air flaps.
By pressing the recirculated air switch (N22s2) on the AAC [KLA] control and operating unit (N22) the fresh air flaps and recirculated air flaps actuator
motor (M2/5) is actuated via the AC bus. In recirculation mode, the recirculation flap is open and the fresh air flap is closed. Air is drawn into the AC
housing from the vehicle interior by the blower.
In fresh air mode, the fresh air flap is open and the recirculation flap is closed. Fresh air is drawn into the automatic air conditioning housing by the
blower.

When the recirculated air switch (N22s2) is operated manually the system goes into 100% recirculated air mode for a limited time.
This is displayed by the function LED. Time limit function:

^

after 30 minutes with outside temperature above approx. 7°C,

^

after 5 minutes with outside temperature below approx. 7° C,

^

after 5 minutes with AC OFF.

After ignition ON, a non-recurring 100 % automatic recirculated air is possible for 30 minutes. After expiry of this period the system switches to 80 %
recirculated air or fresh air, depending upon the conditions.
If automatic recirculated air is required after engine ON, fresh air will be circulated initially for 30 seconds. Following this then 80 % automatic
recirculated air is actuated and 10 seconds later as required then switches to 100 % automatic recirculated air.

Tunnel function
Activation of the tunnel function:

Only possible where the recirculated air LED is not illuminated. pressing the recirculated air switch (N22s2) for more than 1.5 s Reaction: fresh air and
recirculated air flaps are driven into recirculated air position. Now the 4 windows and the tilting/sliding roof are closed in a staggered manner.

If the recirculated air-LED is extinguished manually or by the automatic timer, the fresh air and recirculated air flap moves to the fresh air position,
however, the windows and the sliding roof remain closed.

Deactivation of tunnel function:

Only possible where the recirculated air LED is illuminated. pressing the recirculated air switch (N22s2) for more than 1.5 s Reaction: fresh air and
recirculated air flaps are driven into fresh air position. Now the 4 windows and the tilting/sliding roof are opened in a staggered manner.
If the recirculated air LED is reset manually (operating the recirculated air switch (N22s2) for less than 1.5 seconds), then only the fresh air flap and
recirculated air flap is moved into the recirculated air position

Special functions of the fresh air/recirculated air control:

^

In the AC OFF function no automatic and no pollutant gas- controlled recirculated air is possible.

^

Only fresh air mode is possible in the defrosting function.

^

100% recirculated air applies in the "0" function

^

Manual recirculated air is deleted after ignition OFF.

^

No manual or automatic recirculated air is possible in the rest function.

GF83.40-P-2182-01T Actuator Motor, Automatic Air Conditioning, Task|Page 16169 > < GF83.40-P-2182-01T Actuator Motor, Automatic Air Conditioning, Task|Page 16167