Sunroof / Moonroof Module: Customer Interest
Body - Panoramic/Sliding Roof Synchronization Loss

Date: October 14, 2005

Order No.: P-B-77.20/19b

Supersedes: P-B-77.20/19a dated Sept. 17, 2004

Group: 77

Revision: Warranty Information Updated

SUBJECT: 
Model 211.026/065/070/076/082/083, Up to VIN A609690 and X165949

Intermittent Synchronization Loss from Sliding Roof/Panorama Roof

If you receive customer reports in the above model vehicles of intermittent synchronization loss on sliding roof or panorama roof, the condition may be
the result of the voltage at the overhead control panel (OCP) dropping briefly below 5 volts. It will set DIC code 9032 (supply voltage of control unit
N72/1, upper control panel UCP [OBF] is to low [under voltage]) and it is not the part number listed below. To resolve, please replace the OCP with the
part numbers indicated below.

Parts Information

Note:

The following allowable labor operations should be used when submitting a warranty claim for this repair.

In Case of Warranty, use the table.