Recall - SBC Wire Harness Modifications|Page 619 > < Recall - SBC Wire Harness Modifications|Page 617
Page 25
background image

3.

Disconnect SBC hydraulic unit harness connector (arrow, Figure 4) from SBC hydraulic unit (A) and remove cable tie (B, Figure 5).

4.

Detach the SBC hydraulic unit ground wire harness (arrow, Figure 5) at ground terminal stud (A).

5.

Remove cable tie (arrow, Figure 6) securing SBC wire harness (A) to SBC connector housing (B).