Control Module HVAC: Description and Operation
Electric Suction-Type Fan Control Module (Engine/A/C)

Model

210
with ENGINE111 (except 111.947) as of September 1, 1996

111.947 as of March 1, 1997
112 as of June 1, 1998
611 as of March 3, 1997

with CODE (580) Air Conditioning or Tempmatic A/C for USA
with CODE (581a) Air Conditioning (automatic)

Purpose

The engine/AC electric fan control module (N76) switches on the engine/AC electric fan (M4/3).

Function

The electric suction-type fan control module (engine/A/C) (N76) is controlled by the push-button control module (N19, N22) The electric suction-type
fan control module (engine/A/C) (N76) compares these values with the values stored and increases the speed of the electric suction-type fan
(engine/A/C) (M4/3) from the basic ventilation speed of 20 % (with A/C compressor ON) infinitely up to 100 % under the following conditions:

-

Refrigerant pressure

=

13 bar

-

Coolant temperature

=

103 °C

The speed is reduced to the basic ventilation speed of 20 % under the following conditions:

-

Refrigerant pressure

=

12 bar

-

Coolant temperature

=

100 °C