mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

AN88.50-P-0005T Retrofit Hotel Lock (90 Position)|Page 21808 > < AN88.50-P-0005T Retrofit Hotel Lock (90 Position)|Page 21806
Page 1
background image

Trunk / Liftgate Lock: Service and Repair
AN88.50-P-0005-02T Retrofit Hotel Lock Wiring Harness.

AN88.50-P-0005-02T Retrofit Hotel Lock Wiring Harness.

Special Tools

Complete hotel lock wiring harness.

Component Identification

1. Install contact springs (1).

For line lengths and line cross section, see Parts ordering notes

2. Install round terminal (2) at other end of brown (br) lead.
3. Install contact spring (1) for yellow (ge) lead in chamber "2" of white, 2-pin connector (3).
4. Install contact spring (1) for brown (br) lead in chamber "1" of white, 2-pin connector (3) and lock white, 2-pin connector.

5. Tie yellow (ge) and brown (br) line together with insulation tape, as shown in illustration.

The insulating tape should have a distance of at least 30 mm to the white, 2-pin connector (3).