E 320 Sedan (211.065) V6-3.2L (112.949) (2004)
9.
Check if a pulsation damper (B, Figure 4) was installed on suction hose:
^
If pulsation damper (B) was not installed: Install new standard suction hose (A) to suction line, secure with new hose clamps (arrows).
^
If pulsation damper (B) was installed: Install new suction hose (A) with double pulsation damper to suction line, secure with new hose clamps
(arrows).
10.
Reinstall combination filter housing in reverse order.
11.
Remove cable tie (arrow, Figure 5) securing SBC wire harness (A) to SBC connector housing (B).