21.

Secure ground wiring harness (arrow, Figure 15) to SBC wire harness (A) using two layers of fabric tape (B) in the circled area. Start taping
approximately 35 mm (X = 35 mm, Figure 15) from end of connector cover receptacle (C).

Note:

See last bullet of step 33 note concerning fabric tape placement.

^

Reposition SBC wiring harness with grommet (A, Figure 17) into the forward wall opening (B) in the wire harness guide (C).