Heater Control Valve: Customer Interest
A/C - Erratic Rear A/C Operation/DTC's Set

Date: September 17, 2004

Order No.: P-B-83.20/72

Supersedes:

Group: 83

SUBJECT:
Model 211.026/065/070/076/082/083/265/270/282/283

Rear A/C Intermittently Blows Warm Air in Cooling Mode or No Warm Air in Heating Mode

If you receive customer reports in the above model vehicles that either the rear A/C vent is intermittently blowing warm air in the cooling mode or there
is no warm air in the heating mode, check the heat exchanger shut off valve, M16/32. DTCs 9026 (M16/32 open) and/or 9027 (M16/32 short circuited)
may or may not be stored. A test via actuations" in DAS may indicate that the driver side SAM is malfunctioning. In any case, perform the following test.
Prior to replacing the driver side SAM, perform the following test.

1.

Remove connector M4 from the driver's side SAM.

2.

With a multimeter, check the resistance between pin 9 and pin 12 on the connector just removed.

3.

If the resistance for M16/32 is less than 10 ohms, replace the heat exchanger shut off valve. Do not replace the driver's side SAM.

4.

If the resistance for M16/32 is 10 ohms of more, the heat exchange shut off valve is OK. Continue to diagnose the system as needed.