mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

GF83.40-P-2105-02T Automatic Air Conditioning Box, Function|Page 18215 > < GF83.40-P-2105-02T Automatic Air Conditioning Box, Function|Page 18213
Page 3
background image

Component Identification

Mixed air operation front and rear; recirculated air mode

Function

In "front and rear blend air mode; recirculated air mode" recirculated air (A) is drawn in (A32) due to the position of the fresh air flaps and recirculated
air flaps actuator motor (M2/5). The recirculated air (A) reaches through the cooled evaporator (2) is dried and cooled there. Then part of the dried and
cooled air (B) is heated up again in the heated heat exchanger (3) and heater booster (R22/3) due to the position of the left blend air flap actuator motor
(M2/6) and right blend air flap actuator motor (M2/7). The other part of the dried and cooled air (B) is led past the heat exchanger (3) and heater booster
(R22/3) and mixed downstream of the heat exchanger (3) and heater booster (R22/3) with the heated air (C) to form blend air (D

The blend air (D) is led to the air outlets (5, 6, 7, 8, 9) via the position of the actuator motors for the blend air flap on the left (M2/6) and right (M2/7),
actuator motors for left and right footwell flaps (M2/15) and center outlet flap actuator motor (M2/22). The defrosting flaps can be opened by the left
and right defrosting actuator (M2/16) if the outside air is dry.
The condensation water is led to the outside condensation water drain.