Static test
-

Remove instrument cluster.   See: Instrument Cluster/Service and Repair

-

Open cover (a) on connector housing.

-

Check voltage with multimeter (003) between socket 4 (brown wire, ground) and socket 2 (black/violet wire with red dots, terminal 15). For this
check turn ignition/starter switch to position 2.

Specified value: Battery voltage:  Use electrical connection set 201 589 00 99 00 for testing.

-

Measure resistance with multimeter (003) between socket 4 (brown wire, ground) and socket 3 (white wire, sensor wire).

Specified value: 2 k ohms +/- 200 ohms. Use electrical connection set 201 589 00 99 00 for testing.

Dynamic test with frequency generator
-

Connect frequency generator (032):  Red test wire to socket 3 (white wire, sensor wire). Black test wire to socket 4 (brown wire, ground) Use
electrical connection set 201 589 00 99 00 for testing.

-

Test sensor with (frequency generator in counter mode).

-

Drive vehicle on dynamometer or on road. The frequency should increase continuously at increasing speed.

-

Turn ignition/starter switch to position 2 (battery voltage).

-

Test speedometer with (frequency generator in alternator mode, sine wave function). The speed reading should increase at increasing frequency.